Main feed water pump
WebFeed water pumps (FWP) pump the feed water from the de-aerator through the HP heaters to the heat recovery steam generator. The major characteristic of the FWP is their high differential head. In all sizes of gas-fired combined-cycle power plants, the FWP are horizontal ring section type; occasionally, they could also be barrel or axially split type. WebMain Feed Water Pump-Shanghai Apollo Machinery Co., Ltd. Excellent Elite Team. Centennial Brand. Stock Code:832568. Unified social credit code:91310000734081815D. C N. E N. Home; About Us. Company profile Enterprise culture Enterprise strategy Social responsibility Company executives Partners Staff corner.
Main feed water pump
Did you know?
Web3 apr. 2024 · A flow meter in the main feed line measures the water flow to the boiler. When the flow drops below the minimum flow specified by the pump vendor, a controller begins opening the recycle control ... WebAn open feedwater heater , also called direct-contact and deaerating (DA) heater, is one that heats the feedwater by directly mixing it with bled steam from the turbine. Usually only one DA is used at Power Plant. Because the pressure in such a heater can’t exceed the turbine pressure at the point of extraction, a pump (Main Boiler Feed Water ...
WebCIRC. WATER PUMP RHR PUMP MAIN TURBINE CONDENSATE PUMP MAIN FEED PUMP There are two major systems utilized to convert the h eat generated in the fuel … WebBoiler feed pumps are also referred to as feed pumps (see Reactor pump) and designed as multistage radial flow pumps. (Also see Multistage pump ) They serve to feed a steam …
WebAccordingly, the main feed pump must be high temperature and high-pressure pump since it requires the head larger than the pressure inside the steam generator. Also, from the viewpoint of assuring feed water of the … Web12 apr. 2024 · Boiler pumps, also known as boiler feed pumps, are generally divided into two driving modes: motor and steam turbine. The motor can be an AC motor, so the speed of the boiler feed pump is constant, and the boiler feed water is adjusted by throttling. The boiler feed pump plays a very important role and is called the heart of the heat cycle.
WebPhoto by J.A. Gonyeau. The Feedwater Pump increases the water pressure from about 350 pounds per square inch (psi) to about 1200 pounds per square inch. Each unit typically will have 2 or 3 Feedwater pumps. …
Web5 jun. 2024 · Boiler feed water pumping applications typically require high pressures due to the high temperatures of the feed water. Water changes to a gas state at 212-degrees F … jordan red and yellowWebTurbine Building-Main Feedwater Pump. The Feedwater Pump may be electrically or turbine-driven. In this case, a large electric motor is located on the left hand side of the … jordan red and white 7Web31 aug. 2024 · A feed pump is a type of pump that supplies water to a boiler to produce steam. For industrial purposes, a feed pump supplies a liquid for further processing. … jordan red and black whiteWeb21 apr. 2024 · Open the sea water discharge valve from where the water is sent back to the sea after circulating inside the fresh water generator. Close the vacuum valve situated on top of the generator. Now start the sea … jordan red cherryWeb8 aug. 2024 · Steam turbine auxiliary pump. The feed water pump is a water supply device that delivers high temperature and high pressure to the boiler. In the auxiliary machine, the feed pump consumes the most power, accounting for 3%~4% of the unit’s output power, and has high technical requirements. With the development of the unit to large capacity … jordan red chicagoWebThere are basically two types of boiler feed pumps and they are- Stamped stainless steel vertical multistage inline pumps Multistage horizontal ring section pumps 1. Stamped … jordan red cardinalsWebWater tray around the seal. Make-up water supply with flow indication. overflow routed to a floor drain. (seal water is not recovered) The purpose of the main feedwater pump turning gear is to ? Slowly rotate the turbine shaft to prevent shaft bowing or deflection that might result from non-uniform heating or cooling of the shaft during startup ... jordan red crescent